Summary of example combustion plants of type SICF-S

All information and sizes of plants are available as PDF download on our download page!

SCHLAMM- UND FESTSTOFFVERBRENNUNG
SLUDGE AND SOLID INCINERATION

(Unverbindlich / Non-binding)

Anlagen Typ

Plant type

SICF 200-S

SICF 300-S

SICF 400-S

SICF 500-S

SICF 600-S

SICF 800-S

SICF 1000-S


Verbrennungsmasse

Combustion mass

200

300

400

500

600

800

1000

[kg/h]

Heizwert bis

Calorific value up to

15000

15000

15000

15000

15000

15000

15000

[kJ/kg]

Hauptkammer

Main Chamber









Temperatur

Temperature

850

850

850

850

850

850

850

[°C]

Laenge (Aussen)

Length (Outside)

3800

3800

4600

4800

5600

6900

7100

[mm]

Breite (Aussen)

Width (Outside)

2100

2100

2100

2100

2100

2100

2100

[mm]

Hoehe (Aussen)

Height (Outside)

2100

2100

2600

2700

2900

3200

3200

[mm]

Brenner MCC

Burner MCC









Installierte Leistung min.

Installed burner rating min.

642

936

1284

1605

1927

2569

3211

[kW]

Brenner Installiert

Burner installed

1

1

1

1

1

2

2

[pcs]

Brenner Serie

Burner series

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner


Brenner typ

Burner type

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R


Leistungsbereich

Performance range

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

[kW]

Gewicht MCC

Weight MCC









Stahl

Steel

2440

2440

3209

3396

4025

5095

5222

[kg]

Isolierung und Auflagewand SR

Insulation and support wall SR

9774

9774

13311

14176

17020

21993

22569

[kg]

Gesamtgewicht MCC

Total weight MCC

12214

12214

16520

17572

21045

27088

27791

[kg]

Nachbrennkammer

Afterburner chamber









Temperatur

Temperature

1100

1100

1100

1100

1100

1100

1100

[°C]

Laenge (Aussen)

Length (Outside)

3400

3400

4100

4800

5600

7200

8600

[mm]

Breite (Aussen)

Width (Outside)

2100

2100

2100

2100

2100

2100

2100

[mm]

Hoehe (Aussen)

Height (Outside)

2100

2100

2600

2700

2900

3200

3200

[mm]

Brenner MCC

Auxiliary burner SCC









Installierte Leistung min.

Installed burner rating min.

275

413

550

688

826

1101

1376 (2x688)

[kW]

Brenner Installiert

Burner installed

1

1

1

1

1

1

1

[pcs]

Brenner Serie

Burner series

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner


Brenner typ

Burner type

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R


Leistungsbereich

Performance range

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

[kW]

Gewicht SCC

Weight SCC









Stahl

Steel

2465

2465

3211

3695

4346

5640

6530

[kg]

Isolierung

Insulation

3379

3379

4254

4932

5781

7472

8769

[kg]

Gesamtgewicht SCC

Total weight SCC

5844

5844

7465

8628

10127

13112

15299

[kg]

Gesamtgewicht MCC/SCC

Total weight MCC/SCC

18058

18058

23985

26200

31172

40200

43090

[kg]

Rauchgas

Flue gas









Volumen Betrieb

Volume Operation

7607

11411

15215

19019

22822

30430

38037

[Bm³ Rgfeucht/h]

Verweilzeit Rauchgas min.

Flue gas residence time min.

2,5

2,5

2,5

2,5

2,5

2,5

2,5

[s]

Rauchgasleitung

Flue gas pipe

406

559

559

610

710

800

900

[mm]

Saugzuggeblaese

Induced draft fan









Statischer Druck ρ= 0,75 kg/m³

Static pressure ρ= 0,75 kg/m³

5000

5000

5000

5000

5000

5000

5000

[Pa]

Volumenstrom

Volume flow rate

10753

17069

21336

27310

34137

42671

53766

[m³/h]

Typ

Type

P-PRZ9/355/800/1

P-LRZ9/450/710/1

P-LRZ9B/500/800/1

P-LRZ9C/560/800/1

P-RNZ9/630/800/1

P-RNZ9/710/900/1

P-RNZ9/800/1000/1 (d2 980)


Ventilator Motorleistung

Fan Motor power

30

45

55

75

90

110

132

[kW]

Verbrennungsluft

Combustion air









Ventilator Verbrennungsluft

Fan combustion air









Statischer Druck ρ= 1,20 kg/m³

Static pressure ρ= 1,20 kg/m³

3150

3150

3150

3150

3150

3150

3150

[Pa]

Volumenstrom

Volume flow rate

1717

2683

3381

4293

5366

6761

8586

[m³/h]

Typ

Type

A-MRZ10B/160/500/1

A-MRZ10C/180/530/1

A-MRZ10E/200/530/1

A-MRZ10E/224/600/1

A-MRZ10/250/800/1

A-MRZ10A/280/850/1

A-MRZ10C/315/950/1


Ventilator Motorleistung

Fan Motor power

3

4

5,5

7,5

7,5

11

15

[kW]

ZANNI Rost

ZANNI grate









Rostgroesse

Grate size

4,05

4,05

5,25

5,55

6,75

8,70

9,00

[m²]

ZANNI Luft/Luft Kühler

ZANNI air/air cooler

Single system

Single system

Single system

Single system

Single system

Double system

Double system

[Type]

Eintrittstemperatur Abgas

Inlet temperature flue gas

1100

1100

1100

1100

1100

1100

1100

[°C]

Eintrittstemperatur Kuehlluft

Cooling air inlet temperature

40

40

40

40

40

40

40

[°C]

Massenstrom Rauchgas Ein

Mass flow flue gas in

1952

2927

3903

4879

5855

7806

9758

[kg/h]

Volumenstrom Kuehlluft Ein

Volume flow cooling air in

3887

5919

8128

9718

11485

14135

18553

[Bm³/h]

Ventilator Kuehlluft

Fan cooling air









Statischer Druck ρ= 1,12 kg/m³

Static pressure ρ= 1,12 kg/m³

5000

5000

5000

5000

5000

5000

5000

[Pa]

Volumenstrom

Volume flow rate

4586

7223

9172

11465

14331

14331

22929

[m³/h]

Typ

Type

A-PRZ9/250/560/1

A-LRZ9/355/560/1

A-LRZ9B/400/630/1

A-LRZ9C/450/630/1

A-RNZ9/500/630/1

A-RNZ9/500/630/1

A-RNZ9/560/710/1


Ventilator Motorleistung

Fan Motor power

11

15

18,5

30

30

30

45

[kW]

Ventilator Mischluft Kamin

Fan mixed air chimney









Statischer Druck ρ= 1,20 kg/m³

Static pressure ρ= 1,20 kg/m³

3150

3150

3150

3150

3150

3150

3150

[Pa]

Volumenstrom

Volume flow rate

5366

6761

8586

12878

12878

21464

26830

[m³/h]

Typ

Type

A-LRZ9/315/500/1

A-LRZ9C/355/500/1

A-RNZ9/400/500/1

A-RNZ9/450/560/1

A-RNZ9/450/560/1

A-RNNS6/560/710/1

A-RNSK6/630/800/1


Ventilator Motorleistung

Fan Motor power

7,5

11

11

18,5

18,5

30

37

[kW]

Kuehlluftleitung

Cooling air duct

508

508

508

559

610

630

710

[mm]

Rauchgasleitung Aus

Flue gas pipe Out

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Austrittstemperatur Abgas

Exhaust gas outlet temperature

196,2

199,9

199,8

199,2

197,7

198,6

197,8

[°C]

Austrittstemperatur Kühlluft

Outlet temperature cooling air

440,9

433,3

421,9

439,5

446,4

479,8

459,2

[°C]

Kessel/Energie max.

Boiler/energy max.









Kesselwirkungsgrad max.

Boiler efficiency max.

65

65

65

65

65

65

65

[% Thermisch]

Dampfleistung max.

Steam output max.

730

1096

1461

1826

2191

2922

3652

[kg/h]

Leistung – Elektrisch max.

Power – Electrical max.

175

263

351

438

526

701

877

[kW/h Elektrisch]

Rauchgasfilter

Flue gas filter









Druckluftbedarf

Compressed air requirement

3,1

4,7

6,3

7,8

9,4

12,5

15,6

m³N DL/h

Modulanzahl

Number of modules

2

3

4

5

6

8

8

Stück

Seitenkanalverdichter

Side channel blower









Druck max.

Pressure max.

20000

20000

28000

28000

29000

35000

35000

[Pa]

Volumenstrom max.

Volume flow rate max.

318

318

534

534

660

1050

1050

[Nm³/h]

Typ

Type

2SD 720 – 50/3,00

SD 80 – 50/5,50

2SD 820 – 50/8,50

SD 9 – 50/13,50

1SD 910 – 50/18,5

2SD 920 – 50/16,50

2SD 920 – 50/16,50


Ventilator Motorleistung

Fan Motor power

3,00

5,50

5,50

13,50

18,50

16,50

16,50

[kW]

Kamine

Chimneys









Notkamin

Emergency chimney

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Kühlluftkamin

Cooling air chimney

508

508

508

559

610

630

710

[mm]

Rauchgaskamin

Flue gas chimney

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Grundflaeche gesamt

Footprint overall









Laenge A

Length A

25,3

25,3

25,9

29,0

29,0

33,2

36,5

m

Breite B

Width B

20,8

20,8

25,2

25,2

25,7

25,0

26,4

m

Flaeche

Floor space

526,2

526,2

652,7

730,8

745,3

830,0

963,6

Grundflaeche W2E

Footprint W2E









Laenge C

Length C

8,2

8,2

6,7

7,4

10,0

10,1

10,1

m

Breite D

Width D

4,5

4,5

4,5

4,5

4,5

4,5

4,5

m

Flaeche

Floor space

36,9

36,9

30,2

33,3

45,0

45,5

45,5

Halle Verbrennung

Hall combustion









Laenge

Length

7,2

7,2

8,2

9,8

9,8

11,1

12,1

m

Breite

Width

8,5

8,5

8,4

8,4

8,6

8,6

8,6

m

Flaeche

Floor space

61,2

61,2

68,9

82,3

84,3

95,5

104,1

Ueberdachung von

Roofing of

MCC/SCC

MCC/SCC

MCC/SCC

MCC/SCC

MCC/SCC

MCC

MCC


Freistehend

Freestanding

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

SCC, A/A-C, FH,
Others

SCC, A/A-C, FH,
Others


Zeichnungen

Drawings









Zeichnungsnummern

Drawing numbers

1860-200KG-SR10S-202020000952

1860-300KG-SR10S-202020000952

1860-400KG-SR10S-202020000952

1860-600KG-SR10S-202020000952

1860-600KG-SR10S-202020000952

1860-800KG-SR10S-202020000952

1860-1000KG-SR10S-202020000952


Hinweis

Note

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP | Baugleich/Equal design

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP


Zeichnungsstand

Drawing status

-REV-03

-REV-03

-REV-03

-REV-04

-REV-04

-REV-05

-REV-06


Download Quelle

Download Source

Download

Download

Download

Download

Download

Download

Download


Technisches Datenblatt

Technical data sheet









Version

Version

11/2020

11/2020

11/2020

11/2020

11/2020

11/2020

11/2020


Download Quelle

Download Source

Download

Download

Download

Download

Download

Download

Download


Rev. 2020.11.10










Subject to change.
Sample data only.
Changes to individual parameters can affect all values!

Overview of all SICF plants (200 - 1000 kg/h) - SICF 200 (200 kg/h) - SICF 300 (300 kg/h) - SICF 400 (400 kg/h) - SICF 500 (500 kg/h) - SICF 600 (600 kg/h) - SICF 800 (800 kg/h) - SICF 1000 (1000 kg/h)